Loading...
Munich, Germany
Plant site in the scenario: 16 Psyche, main asteroid belt
ScenarioEngineering
Station · Area 17 · Cargo rack loading and weighing

Corner weighing and lashing station

Area 17 · StationStation control programNot written yet
4 x 1t
Corner load cells
0.33kg
Approximate resolution per cell
28s
Station cycle per rack
DevicesLoad cell, 1 t (x4)Weighing terminal (x4)Air cylinder (x4)Air pressure sensorRadio tag reader and rack tagLaser sensor and light beams
01Engineering

What the station does

Four load cells measure mass and centre of gravity, then four bolts lock the payload.

The rack stands on a short chain section that rests on four load cells, one under each corner. From the four values, the PLC computes mass and centre of gravity. It also finds a rack that rocks on three feet or something touching it.

The driverless vehicle with an ingot bundle arriving at the weigh dock. Render of the digital twin, not a photo.
The driverless vehicle with an ingot bundle arriving at the weigh dock. Render of the digital twin, not a photo.
02

Step by step

28sStation cycle per rack
  1. The PLC sets the empty section to zero and weighs the empty rack.
  2. The vehicle pushes the payload in, slowly for the last 100 mm.
  3. The vehicle withdraws, and a light beam confirms the loading zone is clear.
  4. The scale settles for 2 s and averages the four corners for 3 s.
  5. Mass within 1 % and centre of gravity within ±100 mm pass the check.
  6. Four cylinders push the bolts in, and the rack tag gets its record.
Driven by the PLC
In the twin this station runs under its PLC program, signal by signal. The chart below is drawn from the station signal list. The area page has the film of the running twin, moved live by the PLC.
Enlarge
How the load flows from the payload into the four cells. Drawn from the station signal list, not a recording.
03Engineering

Specifications

The devices

Each device is a real catalogue product. Its own product page will follow on the products level.

DeviceRole
Load cell, 1 t (x4) Carries one corner of the weigh section.
Weighing terminal (x4) Reads one load cell and reports its value.
Air cylinder (x4) Drives one lashing bolt into the payload.
Air pressure sensor Blocks lashing below 5 bar.
Radio tag reader and rack tagReads the rack number, writes the record.
Laser sensor and light beamsPayload at end stop, loading zone clear.

Links lead to the makers' public product pages and are given for reference only. This site is independent work, not affiliated with, sponsored or endorsed by any manufacturer. The makers are responsible for the content of their pages. Trademarks belong to their owners.

The signals

SignalDirectionMeaning
Corner loads 1 to 4to PLCCorner mass in kg from each terminal.
Payload at end stopto PLCThe payload is fully in. Weighing may start.
Loading zone blockedto PLCSomething crosses the loading side of the rack.
Lashing valves 1 to 4from PLCPush the bolts up into the payload.
Air pressureto PLCLashing starts only above 5 bar.
Rack record writefrom PLCRack, payload, mass and centre of gravity.
Notes

About this page

Scenario

In the scenario, every rack that leaves 16 Psyche carries the mass and centre of gravity measured at this station.

Real devices, built from real data

Engineering

Every machine and device in this twin is a real industrial product from the makers' catalogues. They range from sensors, valves and drives to safety scanners, load cells and RFID readers. Each model is built from the product's published data: dimensions, sensing ranges, signals, rated values, parameters and timing.

The PLC programs use the devices' real interfaces and parameters. Before any hardware existed, the twin found hundreds of faults in the plant design and the programs. So a real commissioning would need fine tuning, not a redesign.

Where the work stands

Engineering
Process designComplete
Equipment selectionComplete (real catalogue products)
Device models and PLC driversBuilt and tested against the PLC
Area control programWritten, the first test window against the PLC is next
3D sceneBuilt (line scene) and checked
Station detail scene (millimetre scale)Planned, not built yet
Station signal listWritten: 33 signals, signal layer generated
Station control programNot written yet