Loading...
Munich, Germany
Plant site in the scenario: 16 Psyche, main asteroid belt
ScenarioEngineering
Station · Area 19 · Pad loading tower

Bridge transfer and slot lock

Area 19 · StationStation control programNot written yet
± 1%
Mass check window
4pins
Lock pins per slot
5s
Time to confirm lock
DevicesChain conveyor with 1.5 kW driveLoad cells, 4 x 1 tRadio tag reader and rack tagLight beam sensors (3)Bridge interlock switchAir cylinders with valves (4)
01Engineering

What the station does

Each rack is checked at the landing, crosses the bridge and is locked by four pins.

A 2.4 t rack passes from a steel tower into a ship standing free on the pad. The landing check decides if it may enter: mass within ± 1 %, tag equal to the plan. In the bay, four pins lock it and sensors confirm the lock.

The bridge from the top landing to the cargo bay: a loaded rack on the roller deck between the yellow side guides, entering through the open bay door. The rack is placed for this picture. Render of the digital twin, not a photo.
The bridge from the top landing to the cargo bay: a loaded rack on the roller deck between the yellow side guides, entering through the open bay door. The rack is placed for this picture. Render of the digital twin, not a photo.
02

Step by step

5sTime to confirm lock
  1. The landing conveyor takes the rack and stops it on the scale.
  2. The PLC checks the mass against the rack record within ± 1 %.
  3. The radio tag reader checks the rack identity against the load plan.
  4. With the bridge locked and the door open, the conveyor pushes the rack in.
  5. The ship's lift takes the rack and sets it into its slot.
  6. Four pins enter the rack feet, and sensors confirm the lock within 5 s.
Driven by the PLC
In the twin this station runs under its PLC program, signal by signal. The chart below is drawn from the station signal list. The area page has the film of the running twin, moved live by the PLC.
Enlarge
Signal sequence of one rack, from the scale to the confirmed lock. Drawn from the station signal list, not a recording.
03Engineering

Specifications

The devices

Each device is a real catalogue product. Its own product page will follow on the products level.

DeviceRole
Chain conveyor with 1.5 kW drivePushes the rack over the bridge.
Load cells, 4 x 1 t Weigh the conveyor and rack together.
Radio tag reader and rack tagConfirms the rack identity.
Light beam sensors (3)See the rack on landing, bridge and door.
Bridge interlock switch Blocks raising the bridge during the push.
Air cylinders with valves (4)Drive the lock pins into the rack feet.

Links lead to the makers' public product pages and are given for reference only. This site is independent work, not affiliated with, sponsored or endorsed by any manufacturer. The makers are responsible for the content of their pages. Trademarks belong to their owners.

The signals

SignalDirectionMeaning
Rack massto PLCWeight from four load cells for the check.
Rack tagto PLCIdentity, payload and centre of gravity.
Bridge lowered and lockedto PLCThe push is allowed only with this signal.
Bay door opento PLCShip signal: the side door is open.
Level readyto PLCRack in its slot, pins may lock.
Pin locked and unlockedto PLCFour locked and none unlocked: lock confirmed.
Notes

About this page

Scenario

In the scenario, this bridge is the last stretch a rack crosses on 16 Psyche before the flight to the Earth.

Real devices, built from real data

Engineering

Every machine and device in this twin is a real industrial product from the makers' catalogues. They range from sensors, valves and drives to safety scanners, load cells and RFID readers. Each model is built from the product's published data: dimensions, sensing ranges, signals, rated values, parameters and timing.

The PLC programs use the devices' real interfaces and parameters. Before any hardware existed, the twin found hundreds of faults in the plant design and the programs. So a real commissioning would need fine tuning, not a redesign.

Where the work stands

Engineering
Process designComplete
Equipment selectionComplete (real catalogue products)
Device models and PLC driversBuilt and tested against the PLC
Area control programWritten, in review
3D sceneBuilt (line scene)
Station detail scene (millimetre scale)Planned, not built yet
Station signal listWritten: 41 signals, signal layer generated
Station control programNot written yet